The project includes design of a tunnel to serve the service taxis parking garage in the second basement of Nablus downtown Commercial Complex. The tunnel is about 120m long, and 8.5m wide. The tunnel consists of three parts: the first is not covered, the second is partially covered for pedestrian access, and the third is a closed two story reinforced concrete box section with a total height of 7.5m.
- Design of road.
- Design of tunnel structure
- Design of key intersections
- Coordinated design with infrastructure utilities
- Designed to minimize impacts on existing conditions
UG provided the following services:
- Topographic surveying
- Performing traffic studies and analysis3
- Design of roads and intersections
- Performing the geotechnical studies
- Designing the tunnel structurally to carry the vehicular loading and accordingly the dynamic effect of vehicles, dead load, earthquake force and the stream flow pressure.
- Preparation of bidding documents